Settle plate changer MAS-100 Libra®

Continuous passive air sampling at a new level


The innovative MAS-100 Libra settle plate changer automates plate and lid handling in passive microbial air sampling, taking a proven method to a new level. Manual intervention in critical areas is reduced to a minimum, while cost efficiency and process reliability are increased to an unrivalled level.

The MAS-100 Libra impresses with its small footprint, simple installation and low weight. Alternatively, it can also be used as a mobile unit in the cleanroom.

The automated management of settle plates with the MAS-100 Libra supports you in implementing your contamination control strategy and ensures compliance with EU GMP Annex 1 and associated standards.

  • Automated passive microbial air sampling
  • Sequential exposure of up to 6 standard plates for continuous 24-hour sampling
  • Compact design with minimum space requirement (356 cm²), slim construction (14 cm depth) and low weight (5.3 kg)
  • Flexible application options - permanently installed in containment via tri-clamp mounting or mobile on a table/stand
  • Developed in accordance with GAMP 5, fully validated in accordance with ISO 14698 and EN 17141
  • Suitable for ISO 14644-1 Class 5 / GMP Grade A and portable use in Grade B-D cleanrooms
  • Easy to clean using industry-standard cleaning agents and disinfectants
  • Adjustable exposure times for maximum control

Pharma





Engineering




free and non-binding offer

Get an offer now

We will be happy to provide you with an offer tailored to your needs. Please fill out the following contact form. We will get in touch with you as soon as possible. 

Send request
PERFECT FIT FOR CRITICAL ZONES

MAS-100 Libra – Validated according to GAMP5 standard

  • Flexible agar plate handling: Tested with a variety of 90 mm standard and sealable plates.
  • Excellent flow resistance properties: Minimal turbulence with no risk of backflow onto the exposed agar plate.
  • Low particulate emission: Meets strict criteria for particulate emission in Class A environments.
  • H202 compatibility: Proven through rigorous testing with enzymatic and biological indicators.
  • Advanced error handling: Equipped with intelligent error detection systems that detect operational issues and ensure seamless performance.

TECHNICAL SPECIFICATIONS

  • 1 to 6 agar plates per run covering up to 24 h sampling time
  • Operation with 90 mm standard and lockable agar plates
  • Dimensions: H 28.7 cm, W 25.6 cm, D 13.9 cm
  • Required floor space: 356 cm2
  • Main material: (stainless steel), Sheet: 1.4404, Milled parts:1.4435
  • Operating temperature: 0 to +40 °C
  • Input voltage: 24 V+-10%
  • Power consumption: < 48 W
  • Overvoltage protection: Category 1
  • Average time for agar plate change: 1 min
  • H2O2 compatible

Software

  • Configuration via browser user interface without external software installation
  • Integration into SCADA system or similar control system
  • Control interfaces:
    • Digital input/output channels
    • Modbus TCP
  • Selectable loading and unloading position (same or different)
  • Selectable sampling position (left or right)
  • Configurable sampling time
  • Optional sampling delay










SCOPE OF DELIVERY

  • MAS-100 Libra settle plate changer
  • Tri-clamp connector
  • Tri-clamp sealing gasket
  • Safety sheet
  • Test report
  • Quick Start Guide

Optional accessories:

  • Instrument stand
  • Connector set
  • Remote button
  • Additional Tri-clamp connector
  • Additional Tri-clamp sealing gasket

FAQ - frequently asked questions

Find answers to the most frequently asked questions about the MAS-100 Libra here.

To the FAQ »

Service and Support

Even the best product needs the best service to ensure that it functions perfectly and reliably at all times. As your partner in microbial air monitoring, our service team accompanies you throughout the entire product life cycle. 

To the services »

From Experts for experts

Downloads

BROCHURE

Everything about the MAS-100 Libra settle plate changer

Download »

STEP FILE

Technical 3D model of the
MAS-100 Libra for detailed integration into your planning processes

Request Step File »

ROI CALCULATION

MAS-100 Libra Business Case - Determine the timing of your return on investment

Request ROI calculation »

ARTICLE

MAS-100 Libra: the future of continuous cleanroom monitoring

Download »

ARTICLE

Continuous monitoring: a look at automated settle plate handling

Download »

CONTRIBUTION

The critical role of air sampling for Annex 1 compliance

Download »

ANY QUESTIONS?

Our expert Florian Blum will be happy to assist you. We look forward to hearing from you. 


    +41 44 928 30 80
   welcome@mbv.ch

Book your 30-minutes-online-meeting

MBV NEWSLET­TER

Don't miss out!

Get the latest microbiology air monitoring updates quarterly.

Register now