MICROBIAL AIR SAMPLER MAS-100 NT® 6022
THE CERTIFIED AIR SAMPLER FOR HYGIENE INSPECTIONS ACCORDING TO VDI 6022 AND SWKI VA 104-01
The MAS-100 NT 6022 is the world's only microbial air sampler certified according to VDI 6022. It ensures maximum measurement reliability for hygiene inspections of ventilation and air-conditioning systems in accordance with VDI 6022/ SWKI VA 104-01 and is a seal of quality for the work of a hygiene inspector.
It can be used to determine the germ counts in the supply air and the defined reference air. The comparison of these gives an indication of the microbiological air quality in indoor spaces.
- Certified according to VDI 6022
- Easy cleaning with disinfectants commonly used in the industry
- Integrated mass flow sensor with temperature and pressure compensation for environment-independent air sampling
- Rotatable sampling head for air sampling at side supply air outlets and horizontal air flows
- Programmable start delay to bring the instrument to the correct sampling position
- Compatible with 90mm standard agar plates from manufacturer of choice
Especially for the field of indoor air quality
FREE AND NON-BINDING OFFER
GET AN OFFER NOW
We will be happy to provide you with an offer tailored to your needs. Please fill out the following contact form. We will get in touch with you as soon as possible.
TECHNICAL SPECIFICATIONS
- Air flow rate 100 standard liters per minute (SLPM)
- Accuracy of air flow ±2.5%
- Physical cut off diameter d50 = 1.1um with standard perforated lid 300x0.6mm
- Rechargeable battery, autonomy approx. 5.5 hours (approx. 33'000L)
- Automatic calibration function with MAS-100 Regulus digital anemometer
- Can be used with different agar plate formats
- Height 27cm, Ø 11cm (17cm with handle), weight approx. 2.3kg
Software
- Dialogue-controlled menu operation
- Five pre-programmed sampling volumes, adjustable from 1 to 2000 liters
- Adjustable start delay between 1-120 minutes
- Computer-based software for configuration, qualification and calibration
- Locking of operation via computer software possible (protected mode)
- Programmable sampling sequences
- Five pre-programmed sampling volumes, adjustable from 1 to 2000 liters
- Calibration reminder with the option to lock the instrument when the calibration interval has expired
SCOPE OF DELIVERY
- MAS-100 NT 6022 microbial air sampler
- Perforated lid 300x0.6mm (standard)
- GUI-Lab certificate (supply air measurements according to VDI 6022)
- Calibration certificates for air sampler and digital anemometer (issued by own ISO 17025 accredited calibration laboratory)
- Communication and charging cable with region-specific adapters
- Aluminium dust cover
- Carrying case
- Allen key for adjusting the plate holder
- Template sampling protocol
Tailored to the application
OTHER VERSIONS OF THE MAS-100 NT MODEL
In order to meet the requirements of individual applications even more specifically, various special versions of this popular environmental monitoring instrument have been developed in addition to the standard version of the MAS-100 NT. Our expert Andy Zingre explains in 3 minutes how these versions differ and which applications the special versions of the MAS-100 NT are tailored to.
BASIS VERSION: MAS-100 NT
The world's best-selling microbial air sampler and the base model of the MAS-100 NT 6022. The only difference between the two versions is that the MAS-100 NT does not bear a test label and is not supplied with a certificate.
TAILORED TO ZONE CHANGE: MAS-100 NT HEPA
Specialized in microbiological air monitoring in various cleanroom classes with zone change: the MAS-100 NT with a factory-installed HEPA H13 air outlet filter to protect against carry-over of contamination.
TAILORED TO EXPLOSION RISK: MAS-100 NT EX
Specialized in microbiological air monitoring in rooms with increased risk of explosion: The explosion-proof version of the MAS-100 NT for microbial air sampling in potentially explosive environments.
CLEVERLY DESIGNED
In addition to the sophisticated design made of robust anodized aluminum, the MAS-100 NT 6022 impresses above all with its simple operation and a wide selection of perfectly matched accessories for hygiene inspections.
- Robust hygiene inspection case
- Tube adapter with a tube for access to difficult to reach outlets
- Quick-change adapter to tripod for easy switching between sampling points
- Tripod with a maximum height of 366cm for the sampling of ceiling outlets
- Two sizes of air funnels for induction-free sampling
- Petri dish safety dispenser PSD-10 for safe handling of agar plates
Calibration
All results of active microbial air samplers depend on correct air flow and air volume. That is why we ensure that the calibration of our instruments can be traced back to international standards via the certified MAS-100 Regulus digital anemometer and via our ISO 17025 accredited calibration laboratory. Each step in this cascade is fully documented, giving you the confidence to produce reliable results every time.
To the digital anemometer MAS-100 Regulus »
To our calibration service »
MEASUREMENT RELIABILITY
The tests for the certification of our MAS-100 NT® 6022 were carried out by gui-lab Ing.-Büro Dr. Winkens and were successfully completed in January 2019. The certificate confirms that supply air measurements carried out with the MAS-100 NT comply with the requirements of the guideline VDI 6022 Part 1:2018.
NO CERTIFICATE YET?
You already have a MAS-100 NT 6022 and want to reorder your certificate? No problem! We will send you the certificate and the test label sticker for your MAS-100 NT 6022.
LEARN FROM THE PRO
No experience with the MAS-100 NT 6022 yet? We show the correct use of the entire MAS-100 hygiene inspection set and give practical tips. Our application-oriented YouTube tutorials are available worldwide at any time. Or book us as speakers for your seminar or training.
GOOD TO KNOW
IMPACTION PRINCIPLE in microbial air sampling
For active microbial air sampling based on the impaction principle, a predefined volume of air is drawn through a perforated sieve. The air and the particles in it are accelerated and directed onto an agar plate positioned below the sieve.
Due to inertia, particles above a certain size are impacted onto the agar medium. After appropriate incubation, microbe-bearing particles become visible as colony forming units (CFU), can be counted and reported as CFU/m3. The particle size at which 50% of the particles impact and the other half remain in the air stream is called the cut off diameter d50 (um).
Great emphasis is placed on precision in the manufacture of MBV perforated sieves. This ensures that the cut off diameter is identical in all holes and that microbial air sampling is repeatable.
FROM EXPERTS FOR EXPERTS
Downloads
BROCHURE
"Nothing is easier" - Our offer for hygiene inspections
FACTSHEET
Microbial air sampler
MAS-100 NT 6022 (German)
ARTICLE
Tips for microbial air sampling according to VDI 6022 (German)
ANY QUESTIONS?
Our expert Andy Zingre will be happy to assist you. We look forward to hearing from you.